Use of magnetic fields reduces α‐chaconine, α‐solanine, and total glycoalkaloids in stored potatoes (Solanum tuberosum L.)

This work aimed to assess the suitability of magnetic fields (MF) to reduce glycoalkaloids (GAs) in stored potatoes. The effects of the source of magnetic fields (direct current [DC] and alternating current [AC]), magnetic field intensity (1, 2, and 3 mT), and storage type (dark store-herein referre...

Descripción completa

Detalles Bibliográficos
Autores principales: Irungu, F.G., Tanga, C.M., Ndiritu, F.G., Mwaura, L., Moyo, M., Mahungu, S.M.
Formato: Journal Article
Lenguaje:Inglés
Publicado: Hindawi Limited 2022
Materias:
Acceso en línea:https://hdl.handle.net/10568/120495
_version_ 1855524074668687360
author Irungu, F.G.
Tanga, C.M.
Ndiritu, F.G.
Mwaura, L.
Moyo, M.
Mahungu, S.M.
author_browse Irungu, F.G.
Mahungu, S.M.
Moyo, M.
Mwaura, L.
Ndiritu, F.G.
Tanga, C.M.
author_facet Irungu, F.G.
Tanga, C.M.
Ndiritu, F.G.
Mwaura, L.
Moyo, M.
Mahungu, S.M.
author_sort Irungu, F.G.
collection Repository of Agricultural Research Outputs (CGSpace)
description This work aimed to assess the suitability of magnetic fields (MF) to reduce glycoalkaloids (GAs) in stored potatoes. The effects of the source of magnetic fields (direct current [DC] and alternating current [AC]), magnetic field intensity (1, 2, and 3 mT), and storage type (dark store-herein referred to as the control store and a commercial store with varying light intensity) on quantities of GAs were investigated. Subjecting tubers to increasing levels of MF intensities and placing them in the control store led to a significant (p < .05) decrease in alpha-chaconine and an increase in alpha-solanine. However, storage of potatoes in the commercial store after exposure to increasing MF intensities led to a significant (p < .05) decrease in alpha-solanine and an increase in alpha-chaconine. The use of AC MF with an intensity of 2 mT resulted in a significant (p < .05) reduction in alpha-chaconine, alpha-solanine, and TG. Novelty impact statement Magnetic fields are an emerging non-thermal technology that has wide potential in food processing applications. The findings in the current work revealed that magnetic fields can be used to reduce quantities of toxic glycoalkaloids in potatoes during storage, and thus improve their postharvest quality. The results offer practical insights on postharvest management of potatoes to ensure reduction of losses and thus positively impact food and nutritional security.
format Journal Article
id CGSpace120495
institution CGIAR Consortium
language Inglés
publishDate 2022
publishDateRange 2022
publishDateSort 2022
publisher Hindawi Limited
publisherStr Hindawi Limited
record_format dspace
spelling CGSpace1204952024-05-01T08:17:07Z Use of magnetic fields reduces α‐chaconine, α‐solanine, and total glycoalkaloids in stored potatoes (Solanum tuberosum L.) Irungu, F.G. Tanga, C.M. Ndiritu, F.G. Mwaura, L. Moyo, M. Mahungu, S.M. glycoalkaloids biosynthesis light accumulation metabolites seedlings enzymes solanum tuberosum This work aimed to assess the suitability of magnetic fields (MF) to reduce glycoalkaloids (GAs) in stored potatoes. The effects of the source of magnetic fields (direct current [DC] and alternating current [AC]), magnetic field intensity (1, 2, and 3 mT), and storage type (dark store-herein referred to as the control store and a commercial store with varying light intensity) on quantities of GAs were investigated. Subjecting tubers to increasing levels of MF intensities and placing them in the control store led to a significant (p < .05) decrease in alpha-chaconine and an increase in alpha-solanine. However, storage of potatoes in the commercial store after exposure to increasing MF intensities led to a significant (p < .05) decrease in alpha-solanine and an increase in alpha-chaconine. The use of AC MF with an intensity of 2 mT resulted in a significant (p < .05) reduction in alpha-chaconine, alpha-solanine, and TG. Novelty impact statement Magnetic fields are an emerging non-thermal technology that has wide potential in food processing applications. The findings in the current work revealed that magnetic fields can be used to reduce quantities of toxic glycoalkaloids in potatoes during storage, and thus improve their postharvest quality. The results offer practical insights on postharvest management of potatoes to ensure reduction of losses and thus positively impact food and nutritional security. 2022-11 2022-08-10T02:53:25Z 2022-08-10T02:53:25Z Journal Article https://hdl.handle.net/10568/120495 en Limited Access Hindawi Limited Irungu, F.G.; Tanga, C.M.; Ndiritu, F.G.; Mwaura, L.; Moyo, M.; Mahungu, S.M. 2022. Use of magnetic fields reduces α‐chaconine, α‐solanine, and total glycoalkaloids in stored potatoes (Solanum tuberosum L.). Journal of Food Processing and Preservation. ISSN 1745-4549.
spellingShingle glycoalkaloids
biosynthesis
light
accumulation
metabolites
seedlings
enzymes
solanum tuberosum
Irungu, F.G.
Tanga, C.M.
Ndiritu, F.G.
Mwaura, L.
Moyo, M.
Mahungu, S.M.
Use of magnetic fields reduces α‐chaconine, α‐solanine, and total glycoalkaloids in stored potatoes (Solanum tuberosum L.)
title Use of magnetic fields reduces α‐chaconine, α‐solanine, and total glycoalkaloids in stored potatoes (Solanum tuberosum L.)
title_full Use of magnetic fields reduces α‐chaconine, α‐solanine, and total glycoalkaloids in stored potatoes (Solanum tuberosum L.)
title_fullStr Use of magnetic fields reduces α‐chaconine, α‐solanine, and total glycoalkaloids in stored potatoes (Solanum tuberosum L.)
title_full_unstemmed Use of magnetic fields reduces α‐chaconine, α‐solanine, and total glycoalkaloids in stored potatoes (Solanum tuberosum L.)
title_short Use of magnetic fields reduces α‐chaconine, α‐solanine, and total glycoalkaloids in stored potatoes (Solanum tuberosum L.)
title_sort use of magnetic fields reduces α chaconine α solanine and total glycoalkaloids in stored potatoes solanum tuberosum l
topic glycoalkaloids
biosynthesis
light
accumulation
metabolites
seedlings
enzymes
solanum tuberosum
url https://hdl.handle.net/10568/120495
work_keys_str_mv AT irungufg useofmagneticfieldsreducesachaconineasolanineandtotalglycoalkaloidsinstoredpotatoessolanumtuberosuml
AT tangacm useofmagneticfieldsreducesachaconineasolanineandtotalglycoalkaloidsinstoredpotatoessolanumtuberosuml
AT ndiritufg useofmagneticfieldsreducesachaconineasolanineandtotalglycoalkaloidsinstoredpotatoessolanumtuberosuml
AT mwaural useofmagneticfieldsreducesachaconineasolanineandtotalglycoalkaloidsinstoredpotatoessolanumtuberosuml
AT moyom useofmagneticfieldsreducesachaconineasolanineandtotalglycoalkaloidsinstoredpotatoessolanumtuberosuml
AT mahungusm useofmagneticfieldsreducesachaconineasolanineandtotalglycoalkaloidsinstoredpotatoessolanumtuberosuml