The effect of PhageGuard intervention on Escherichia coli O157:H7 applied to beef hides

An in-plant study was conducted to assess the antimicrobial effectiveness of the Phage Guard intervention against E. coli O157:H7 in cattle stalls before slaughter. The reduction in microbial surface area was evaluated by collecting 500-600 cm2 hide samples from the cleanest area of the cattle durin...

Full description

Bibliographic Details
Main Author: Martinez G., Andres I.
Other Authors: Miller, Markus
Format: Tesis
Language:Inglés
Published: Zamorano: Escuela Agrícola Panamericana 2024
Subjects:
Online Access:https://bdigital.zamorano.edu/handle/11036/7748
id ZAMORANO7748
record_format dspace
spelling ZAMORANO77482024-01-11T10:59:33Z The effect of PhageGuard intervention on Escherichia coli O157:H7 applied to beef hides Martinez G., Andres I. Miller, Markus Brashears, Mindy phage cocktail drop dilution phage hatching lysis phase An in-plant study was conducted to assess the antimicrobial effectiveness of the Phage Guard intervention against E. coli O157:H7 in cattle stalls before slaughter. The reduction in microbial surface area was evaluated by collecting 500-600 cm2 hide samples from the cleanest area of the cattle during slaughter at the Gordon W. Davis Meat Laboratory. Three replicates, each comprising nine beef hide samples, were obtained. These samples were inoculated with an E. coli O157:H7 cocktail via spray application. Throughout the study, periodic collections of inoculated hide samples were performed, and bacterial loads were quantified using the Drop Dilution method and TEMPO System. The TEMPO System proved to be the most suitable and accurate method for quantifying E. coli O157:H7 on beef cattle hides. The study's findings revealed no significant differences between treatments. Potential factors contributing to this outcome included the chosen temperature and exposure time for the bacteriophage's optimal hatching, growth, multiplication, and lysis, typically 37 °C and 30 minutes. However, under the specified conditions, a substantial reduction in E. coli O157:H7 with the PhageGuard E product was not observed. In conclusion, the environmental temperature and exposure time (15 minutes), considering the minimum wait time for beef cattle before slaughter, were insufficient to produce significant reductions in bacteria. 2024-01-11T16:55:46Z 2024-01-11T16:55:46Z 2023 Thesis https://hdl.handle.net/11036/7748 eng Copyright Escuela Agrícola Panamericana, Zamorano https://creativecommons.org/licenses/by-nc-nd/3.0/es/ application/pdf Zamorano: Escuela Agrícola Panamericana
institution Universidad Zamorano
collection Biblioteca Digital Zamorano
language Inglés
topic phage cocktail
drop dilution
phage hatching
lysis phase
spellingShingle phage cocktail
drop dilution
phage hatching
lysis phase
Martinez G., Andres I.
The effect of PhageGuard intervention on Escherichia coli O157:H7 applied to beef hides
description An in-plant study was conducted to assess the antimicrobial effectiveness of the Phage Guard intervention against E. coli O157:H7 in cattle stalls before slaughter. The reduction in microbial surface area was evaluated by collecting 500-600 cm2 hide samples from the cleanest area of the cattle during slaughter at the Gordon W. Davis Meat Laboratory. Three replicates, each comprising nine beef hide samples, were obtained. These samples were inoculated with an E. coli O157:H7 cocktail via spray application. Throughout the study, periodic collections of inoculated hide samples were performed, and bacterial loads were quantified using the Drop Dilution method and TEMPO System. The TEMPO System proved to be the most suitable and accurate method for quantifying E. coli O157:H7 on beef cattle hides. The study's findings revealed no significant differences between treatments. Potential factors contributing to this outcome included the chosen temperature and exposure time for the bacteriophage's optimal hatching, growth, multiplication, and lysis, typically 37 °C and 30 minutes. However, under the specified conditions, a substantial reduction in E. coli O157:H7 with the PhageGuard E product was not observed. In conclusion, the environmental temperature and exposure time (15 minutes), considering the minimum wait time for beef cattle before slaughter, were insufficient to produce significant reductions in bacteria.
author2 Miller, Markus
author_facet Miller, Markus
Martinez G., Andres I.
format Tesis
author Martinez G., Andres I.
author_sort Martinez G., Andres I.
title The effect of PhageGuard intervention on Escherichia coli O157:H7 applied to beef hides
title_short The effect of PhageGuard intervention on Escherichia coli O157:H7 applied to beef hides
title_full The effect of PhageGuard intervention on Escherichia coli O157:H7 applied to beef hides
title_fullStr The effect of PhageGuard intervention on Escherichia coli O157:H7 applied to beef hides
title_full_unstemmed The effect of PhageGuard intervention on Escherichia coli O157:H7 applied to beef hides
title_sort effect of phageguard intervention on escherichia coli o157:h7 applied to beef hides
publisher Zamorano: Escuela Agrícola Panamericana
publishDate 2024
url https://bdigital.zamorano.edu/handle/11036/7748
work_keys_str_mv AT martinezgandresi theeffectofphageguardinterventiononescherichiacolio157h7appliedtobeefhides
AT martinezgandresi effectofphageguardinterventiononescherichiacolio157h7appliedtobeefhides
_version_ 1808119630122713088