Energikartläggning vid biogasanläggningen, Kungsängens gård

The purpose of this thesis was to make an energy survey and quantify energy flows of individual unit operations associated with the biogas production in Uppsala Vatten och Avfall AB:s biogas plant, located at Kungsängens gård. Moreover, large consumers of energy would be identified and analyzed....

Descripción completa

Detalles Bibliográficos
Autor principal: Andersson, Mats
Formato: Second cycle, A2E
Lenguaje:sueco
sueco
Publicado: 2011
Materias:
Acceso en línea:https://stud.epsilon.slu.se/2300/
_version_ 1855570414503198720
author Andersson, Mats
author_browse Andersson, Mats
author_facet Andersson, Mats
author_sort Andersson, Mats
collection Epsilon Archive for Student Projects
description The purpose of this thesis was to make an energy survey and quantify energy flows of individual unit operations associated with the biogas production in Uppsala Vatten och Avfall AB:s biogas plant, located at Kungsängens gård. Moreover, large consumers of energy would be identified and analyzed. The objective of this energy survey was to obtain a detailed understanding of the energy use in the biogas production. The energy survey was divided into two parts: electricity and heat. Each part was treated separately and with somewhat different approach. To estimate the electricity usage during the projcet the rated power of each selected unit operation was noted and multplied with the measured time of usage. By doing that the total amount of energy consumed is obtained. During the project a total amount of 152 kWh/ton electricity was used. The 12 largest electricity consumers had a combined usage of 106 kWh/ton, corrresponding to 70 %. The heat survey was subdivided into hot water and steam. Hot water is used to keep the biogas digesters and facilities warm. Steam is exclusively used in the heat pretreatment. Thermal energy consumption was as following: · Keeping the biogas digester warm consumed close to 20 % of the total heating demand, corresponding to 40,8 kWh/ton. · Heat pretreatment accounted for 62 % of the total heating demand, corresponding to 129 kWh/ton. · Heating demand for other staff facilities accounted for 18 % of the total heating demand, corresponding to 37,7 kWh/ton.
format Second cycle, A2E
id RepoSLU2300
institution Swedish University of Agricultural Sciences
language swe
swe
publishDate 2011
publishDateSort 2011
record_format eprints
spelling RepoSLU23002014-01-15T15:45:32Z https://stud.epsilon.slu.se/2300/ Energikartläggning vid biogasanläggningen, Kungsängens gård Andersson, Mats Renewable energy resources The purpose of this thesis was to make an energy survey and quantify energy flows of individual unit operations associated with the biogas production in Uppsala Vatten och Avfall AB:s biogas plant, located at Kungsängens gård. Moreover, large consumers of energy would be identified and analyzed. The objective of this energy survey was to obtain a detailed understanding of the energy use in the biogas production. The energy survey was divided into two parts: electricity and heat. Each part was treated separately and with somewhat different approach. To estimate the electricity usage during the projcet the rated power of each selected unit operation was noted and multplied with the measured time of usage. By doing that the total amount of energy consumed is obtained. During the project a total amount of 152 kWh/ton electricity was used. The 12 largest electricity consumers had a combined usage of 106 kWh/ton, corrresponding to 70 %. The heat survey was subdivided into hot water and steam. Hot water is used to keep the biogas digesters and facilities warm. Steam is exclusively used in the heat pretreatment. Thermal energy consumption was as following: · Keeping the biogas digester warm consumed close to 20 % of the total heating demand, corresponding to 40,8 kWh/ton. · Heat pretreatment accounted for 62 % of the total heating demand, corresponding to 129 kWh/ton. · Heating demand for other staff facilities accounted for 18 % of the total heating demand, corresponding to 37,7 kWh/ton. 2011-02-22 Second cycle, A2E NonPeerReviewed application/pdf swe https://stud.epsilon.slu.se/2300/1/andersson_m_110222.pdf Andersson, Mats, 2011. Energikartläggning vid biogasanläggningen, Kungsängens gård. Second cycle, A2E. Uppsala: (NL, NJ) > Dept. of Energy and Technology <https://stud.epsilon.slu.se/view/divisions/OID-565.html> urn:nbn:se:slu:epsilon-8-976 swe
spellingShingle Renewable energy resources
Andersson, Mats
Energikartläggning vid biogasanläggningen, Kungsängens gård
title Energikartläggning vid biogasanläggningen, Kungsängens gård
title_full Energikartläggning vid biogasanläggningen, Kungsängens gård
title_fullStr Energikartläggning vid biogasanläggningen, Kungsängens gård
title_full_unstemmed Energikartläggning vid biogasanläggningen, Kungsängens gård
title_short Energikartläggning vid biogasanläggningen, Kungsängens gård
title_sort energikartläggning vid biogasanläggningen, kungsängens gård
topic Renewable energy resources
url https://stud.epsilon.slu.se/2300/
https://stud.epsilon.slu.se/2300/