Energikartläggning vid biogasanläggningen, Kungsängens gård
The purpose of this thesis was to make an energy survey and quantify energy flows of individual unit operations associated with the biogas production in Uppsala Vatten och Avfall AB:s biogas plant, located at Kungsängens gård. Moreover, large consumers of energy would be identified and analyzed....
| Autor principal: | |
|---|---|
| Formato: | Second cycle, A2E |
| Lenguaje: | sueco sueco |
| Publicado: |
2011
|
| Materias: | |
| Acceso en línea: | https://stud.epsilon.slu.se/2300/ |
| _version_ | 1855570414503198720 |
|---|---|
| author | Andersson, Mats |
| author_browse | Andersson, Mats |
| author_facet | Andersson, Mats |
| author_sort | Andersson, Mats |
| collection | Epsilon Archive for Student Projects |
| description | The purpose of this thesis was to make an energy survey and quantify energy flows of
individual unit operations associated with the biogas production in Uppsala Vatten och Avfall
AB:s biogas plant, located at Kungsängens gård. Moreover, large consumers of energy would
be identified and analyzed. The objective of this energy survey was to obtain a detailed
understanding of the energy use in the biogas production.
The energy survey was divided into two parts: electricity and heat. Each part was treated
separately and with somewhat different approach. To estimate the electricity usage during the
projcet the rated power of each selected unit operation was noted and multplied with the
measured time of usage. By doing that the total amount of energy consumed is obtained.
During the project a total amount of 152 kWh/ton electricity was used. The 12 largest
electricity consumers had a combined usage of 106 kWh/ton, corrresponding to 70 %.
The heat survey was subdivided into hot water and steam. Hot water is used to keep the
biogas digesters and facilities warm. Steam is exclusively used in the heat pretreatment.
Thermal energy consumption was as following:
· Keeping the biogas digester warm consumed close to 20 % of the total heating
demand, corresponding to 40,8 kWh/ton.
· Heat pretreatment accounted for 62 % of the total heating demand, corresponding to
129 kWh/ton.
· Heating demand for other staff facilities accounted for 18 % of the total heating
demand, corresponding to 37,7 kWh/ton. |
| format | Second cycle, A2E |
| id | RepoSLU2300 |
| institution | Swedish University of Agricultural Sciences |
| language | swe swe |
| publishDate | 2011 |
| publishDateSort | 2011 |
| record_format | eprints |
| spelling | RepoSLU23002014-01-15T15:45:32Z https://stud.epsilon.slu.se/2300/ Energikartläggning vid biogasanläggningen, Kungsängens gård Andersson, Mats Renewable energy resources The purpose of this thesis was to make an energy survey and quantify energy flows of individual unit operations associated with the biogas production in Uppsala Vatten och Avfall AB:s biogas plant, located at Kungsängens gård. Moreover, large consumers of energy would be identified and analyzed. The objective of this energy survey was to obtain a detailed understanding of the energy use in the biogas production. The energy survey was divided into two parts: electricity and heat. Each part was treated separately and with somewhat different approach. To estimate the electricity usage during the projcet the rated power of each selected unit operation was noted and multplied with the measured time of usage. By doing that the total amount of energy consumed is obtained. During the project a total amount of 152 kWh/ton electricity was used. The 12 largest electricity consumers had a combined usage of 106 kWh/ton, corrresponding to 70 %. The heat survey was subdivided into hot water and steam. Hot water is used to keep the biogas digesters and facilities warm. Steam is exclusively used in the heat pretreatment. Thermal energy consumption was as following: · Keeping the biogas digester warm consumed close to 20 % of the total heating demand, corresponding to 40,8 kWh/ton. · Heat pretreatment accounted for 62 % of the total heating demand, corresponding to 129 kWh/ton. · Heating demand for other staff facilities accounted for 18 % of the total heating demand, corresponding to 37,7 kWh/ton. 2011-02-22 Second cycle, A2E NonPeerReviewed application/pdf swe https://stud.epsilon.slu.se/2300/1/andersson_m_110222.pdf Andersson, Mats, 2011. Energikartläggning vid biogasanläggningen, Kungsängens gård. Second cycle, A2E. Uppsala: (NL, NJ) > Dept. of Energy and Technology <https://stud.epsilon.slu.se/view/divisions/OID-565.html> urn:nbn:se:slu:epsilon-8-976 swe |
| spellingShingle | Renewable energy resources Andersson, Mats Energikartläggning vid biogasanläggningen, Kungsängens gård |
| title | Energikartläggning vid biogasanläggningen, Kungsängens gård |
| title_full | Energikartläggning vid biogasanläggningen, Kungsängens gård |
| title_fullStr | Energikartläggning vid biogasanläggningen, Kungsängens gård |
| title_full_unstemmed | Energikartläggning vid biogasanläggningen, Kungsängens gård |