Indirect systolic blood pressure measurements in cats

Blood pressure (BP) measurements in cats are performed regularly in the clinical setting. As cats are easily stressed by their surroundings, the so-called white coat effect can easily influence the measurements obtained in the clinical environment. For some animals this could lead to a false diag...

Descripción completa

Detalles Bibliográficos
Autor principal: Wlosinska, Julia
Formato: Second cycle, A2E
Lenguaje:sueco
Inglés
Publicado: 2022
Materias:
Acceso en línea:https://stud.epsilon.slu.se/17617/
_version_ 1855572925378199552
author Wlosinska, Julia
author_browse Wlosinska, Julia
author_facet Wlosinska, Julia
author_sort Wlosinska, Julia
collection Epsilon Archive for Student Projects
description Blood pressure (BP) measurements in cats are performed regularly in the clinical setting. As cats are easily stressed by their surroundings, the so-called white coat effect can easily influence the measurements obtained in the clinical environment. For some animals this could lead to a false diagnosis of hypertension. On the other hand, true hypertension that is not diagnosed (and therefore not treated) might eventually lead to damage of target organs. Therefore, reliable BP measurements are a very important part of the clinical handling of feline patients. In order to minimize anxiety-induced rises in blood pressure, it is essential to perform blood pressure measurements in cats using a stress-reduced measurement process. This includes, amongst others, having the owner present, using a quiet location with dimmed lights as well as allowing the cat to acclimatize to its surroundings before beginning the measurements. Following a stress-reduced blood pressure protocol might enable the cat to relax and eventually reach a lower plateau in its blood pressure measurement results. The primary purpose of this study was to examine whether a prolonged measurement time can allow the cat to acclimatize to a clinical environment to such an extent that it lowers the cat’s stress level and, in turn, generates a more distinct plateau of lower BP measurement results. Another purpose was to examine the owner’s perception of performing a BP measurement on their cat themselves when using an automated indirect BP measuring device. A total of 37 cats were included in the study. Twenty-six cats were subject to a prolonged measurement procedure. A clear downward trend was seen in recorded BP for most of the cats during the prolonged measurement time. During the prolonged measurement time, a median number of five additional BP measurements were performed. Most owners in this study reported it to be easy to perform BP measurements on their cats. The study concludes that a prolonged BP measurement time will in general result in lower BP values. By prolonging the BP measurement time, the white coat effect can be reduced in some cats. According to this study, a prolonged BP measurement time should be recommended for cats with initially high BP measurement results. The study also concludes that it is beneficial to allow the cat owner to perform BP measurements on their animal themselves, if and when possible.
format Second cycle, A2E
id RepoSLU17617
institution Swedish University of Agricultural Sciences
language Swedish
Inglés
publishDate 2022
publishDateSort 2022
record_format eprints
spelling RepoSLU176172022-03-15T02:01:12Z https://stud.epsilon.slu.se/17617/ Indirect systolic blood pressure measurements in cats Wlosinska, Julia Animal diseases Blood pressure (BP) measurements in cats are performed regularly in the clinical setting. As cats are easily stressed by their surroundings, the so-called white coat effect can easily influence the measurements obtained in the clinical environment. For some animals this could lead to a false diagnosis of hypertension. On the other hand, true hypertension that is not diagnosed (and therefore not treated) might eventually lead to damage of target organs. Therefore, reliable BP measurements are a very important part of the clinical handling of feline patients. In order to minimize anxiety-induced rises in blood pressure, it is essential to perform blood pressure measurements in cats using a stress-reduced measurement process. This includes, amongst others, having the owner present, using a quiet location with dimmed lights as well as allowing the cat to acclimatize to its surroundings before beginning the measurements. Following a stress-reduced blood pressure protocol might enable the cat to relax and eventually reach a lower plateau in its blood pressure measurement results. The primary purpose of this study was to examine whether a prolonged measurement time can allow the cat to acclimatize to a clinical environment to such an extent that it lowers the cat’s stress level and, in turn, generates a more distinct plateau of lower BP measurement results. Another purpose was to examine the owner’s perception of performing a BP measurement on their cat themselves when using an automated indirect BP measuring device. A total of 37 cats were included in the study. Twenty-six cats were subject to a prolonged measurement procedure. A clear downward trend was seen in recorded BP for most of the cats during the prolonged measurement time. During the prolonged measurement time, a median number of five additional BP measurements were performed. Most owners in this study reported it to be easy to perform BP measurements on their cats. The study concludes that a prolonged BP measurement time will in general result in lower BP values. By prolonging the BP measurement time, the white coat effect can be reduced in some cats. According to this study, a prolonged BP measurement time should be recommended for cats with initially high BP measurement results. The study also concludes that it is beneficial to allow the cat owner to perform BP measurements on their animal themselves, if and when possible. 2022-03-09 Second cycle, A2E NonPeerReviewed application/pdf sv https://stud.epsilon.slu.se/17617/1/wlosinska_j_220120.pdf Wlosinska, Julia, 2022. Indirect systolic blood pressure measurements in cats : improved reliability with prolonged measurement time. Second cycle, A2E. Uppsala: (VH) > Dept. of Clinical Sciences (until 231231) <https://stud.epsilon.slu.se/view/divisions/OID-715.html> urn:nbn:se:slu:epsilon-s-17617 eng
spellingShingle Animal diseases
Wlosinska, Julia
Indirect systolic blood pressure measurements in cats
title Indirect systolic blood pressure measurements in cats
title_full Indirect systolic blood pressure measurements in cats
title_fullStr Indirect systolic blood pressure measurements in cats
title_full_unstemmed Indirect systolic blood pressure measurements in cats
title_short Indirect systolic blood pressure measurements in cats
title_sort indirect systolic blood pressure measurements in cats
topic Animal diseases
url https://stud.epsilon.slu.se/17617/
https://stud.epsilon.slu.se/17617/