Energieffektivisering av dricksvattendistribution : dataanalys och simulering av pumpdrift vid Görvälns vattenverk

This project investigates the efficiency of the water distribution system from Görväln's pumping station to Norrvatten's central consumption zone. The goal is to propose actions that lead to enhanced energy efficiency. The project evaluates the operation of the pumps that transport the drinking wate...

Descripción completa

Detalles Bibliográficos
Autor principal: Thorstensson, Anton
Formato: L3
Lenguaje:sueco
Inglés
Publicado: SLU/Dept. of Energy and Technology 2020
Materias:
_version_ 1855572698810286080
author Thorstensson, Anton
author_browse Thorstensson, Anton
author_facet Thorstensson, Anton
author_sort Thorstensson, Anton
collection Epsilon Archive for Student Projects
description This project investigates the efficiency of the water distribution system from Görväln's pumping station to Norrvatten's central consumption zone. The goal is to propose actions that lead to enhanced energy efficiency. The project evaluates the operation of the pumps that transport the drinking water, and simulates the distribution with a focus on Tunberget's high reservoir. The analysis is done using a dense dataset of measurement from pressure, flow and level sensors in the system. First, the pumps have been analyzed individually as far as possible. Further, all possible combinations of the six pumps used are also analyzed. The modeling of the system is done in MatLab Simulink and adjusted to the empirical conditions that apply to the real system. The project also investigates the possibilities of create consumption forecasts with machine learning algorithms and using these to improve the distribution system. The results shows that there exists a potential for energy efficiency. The greatest potential is found in the pump operation and in the choice of favorable pump combinations. The implementation of consumption forecasts increases delivery security but also reduce energy consumption to a certain extent. The total energy efficiency improvement is estimated at 257 MWh annually, corresponding to 2.4 % of the water pumps' total energy consumption in 2019.
format L3
id RepoSLU16145
institution Swedish University of Agricultural Sciences
language swe
Inglés
publishDate 2020
publishDateSort 2020
publisher SLU/Dept. of Energy and Technology
publisherStr SLU/Dept. of Energy and Technology
record_format eprints
spelling RepoSLU161452020-10-10T01:03:34Z Energieffektivisering av dricksvattendistribution : dataanalys och simulering av pumpdrift vid Görvälns vattenverk Energy performance of drinking water distribution : data analysis and simulation of pump operation Thorstensson, Anton norrvatten förbrukningsprognos renvattenpumpar högreservoarer vattentorn fyllnadskrav This project investigates the efficiency of the water distribution system from Görväln's pumping station to Norrvatten's central consumption zone. The goal is to propose actions that lead to enhanced energy efficiency. The project evaluates the operation of the pumps that transport the drinking water, and simulates the distribution with a focus on Tunberget's high reservoir. The analysis is done using a dense dataset of measurement from pressure, flow and level sensors in the system. First, the pumps have been analyzed individually as far as possible. Further, all possible combinations of the six pumps used are also analyzed. The modeling of the system is done in MatLab Simulink and adjusted to the empirical conditions that apply to the real system. The project also investigates the possibilities of create consumption forecasts with machine learning algorithms and using these to improve the distribution system. The results shows that there exists a potential for energy efficiency. The greatest potential is found in the pump operation and in the choice of favorable pump combinations. The implementation of consumption forecasts increases delivery security but also reduce energy consumption to a certain extent. The total energy efficiency improvement is estimated at 257 MWh annually, corresponding to 2.4 % of the water pumps' total energy consumption in 2019. SLU/Dept. of Energy and Technology 2020 L3 swe eng https://stud.epsilon.slu.se/16145/
spellingShingle norrvatten
förbrukningsprognos
renvattenpumpar
högreservoarer
vattentorn
fyllnadskrav
Thorstensson, Anton
Energieffektivisering av dricksvattendistribution : dataanalys och simulering av pumpdrift vid Görvälns vattenverk
title Energieffektivisering av dricksvattendistribution : dataanalys och simulering av pumpdrift vid Görvälns vattenverk
title_full Energieffektivisering av dricksvattendistribution : dataanalys och simulering av pumpdrift vid Görvälns vattenverk
title_fullStr Energieffektivisering av dricksvattendistribution : dataanalys och simulering av pumpdrift vid Görvälns vattenverk
title_full_unstemmed Energieffektivisering av dricksvattendistribution : dataanalys och simulering av pumpdrift vid Görvälns vattenverk
title_short Energieffektivisering av dricksvattendistribution : dataanalys och simulering av pumpdrift vid Görvälns vattenverk
title_sort energieffektivisering av dricksvattendistribution : dataanalys och simulering av pumpdrift vid görvälns vattenverk
topic norrvatten
förbrukningsprognos
renvattenpumpar
högreservoarer
vattentorn
fyllnadskrav