Sensitivity and specificity of antigen-capture ELISAs for diagnosis of Trypanosoma congolense and Trypansoma vivax infections in cattle

Sensitivity and specificity of the FAO/IAEA kits for diagnosis of bovine trypanosomosis were investigated using sera from experimental cattle infected by tsetse challenge with cloned populations of Trypanosoma congolense (three populations) or T. vivax (one population). The kits are based on monoclo...

Descripción completa

Detalles Bibliográficos
Autores principales: Eisler, M.C., Lessard, P., Masake, R.A., Moloo, S.K., Peregrine, A.S.
Formato: Journal Article
Lenguaje:Inglés
Publicado: Elsevier 1998
Materias:
Acceso en línea:https://hdl.handle.net/10568/33243
_version_ 1855521421951762432
author Eisler, M.C.
Lessard, P.
Masake, R.A.
Moloo, S.K.
Peregrine, A.S.
author_browse Eisler, M.C.
Lessard, P.
Masake, R.A.
Moloo, S.K.
Peregrine, A.S.
author_facet Eisler, M.C.
Lessard, P.
Masake, R.A.
Moloo, S.K.
Peregrine, A.S.
author_sort Eisler, M.C.
collection Repository of Agricultural Research Outputs (CGSpace)
description Sensitivity and specificity of the FAO/IAEA kits for diagnosis of bovine trypanosomosis were investigated using sera from experimental cattle infected by tsetse challenge with cloned populations of Trypanosoma congolense (three populations) or T. vivax (one population). The kits are based on monoclonal antibodies that recognise internal antigens of tsetse-transmitted trypanosomes. Ten cattle were infected with each trypanosome population for at least 60 days, and in combination with unifected cohorts (n=16) were used in a double-blind study design. Sensitivity and specificity of the tests depended on the choice of positive-negative thresholds expressed as percent positivity with respect to the median OD of four replicates of the strong positive reference serum provided with the kit. In general, while overall specificities were high, sensitivities of the antigen-ELISAs were poor. For example, at a cut-off of 5% positivity, the sensitivities of the antigen-ELISAs were 11% for samples (n=1162) from T. congolense infected cattle (n=30), and 24 % for samples (n=283) from T. vivax infected cattle (n=10). The corresponding specificity values were 95% and 79%, respectively. At a cut-off of 2.5% positivity, sensitivity for T. congolense was 25%, and for T.vivax 35%; corresponding specificity values were 85% and 63% respectively. There were no values of the positive-negative threshold at which both sensitivity and specificity were satisfactory. Restricting the analyses to samples taken more than 2 weeks after tsetse challenge did little to improve sensitivity estimates. Trypanosome species specificities of the antigen-ELISAs were also poor. Sensitivity and species specificity of the antigen-ELISA for Typanosoma brucei infections were not investigated. In contrast to the antigen-ELISA, the sensitivity of the buffy-coat technique when applied to the same experimental animals was fairly high at 67% for T. congolense infections and 60 for T. vivax infections. For samples taken more than 2 weeks after tsetse challenge, high sensitivity estimates of 96% for T. congolense and 76% for T. vivax infections were obtained.
format Journal Article
id CGSpace33243
institution CGIAR Consortium
language Inglés
publishDate 1998
publishDateRange 1998
publishDateSort 1998
publisher Elsevier
publisherStr Elsevier
record_format dspace
spelling CGSpace332432024-04-25T06:00:43Z Sensitivity and specificity of antigen-capture ELISAs for diagnosis of Trypanosoma congolense and Trypansoma vivax infections in cattle Eisler, M.C. Lessard, P. Masake, R.A. Moloo, S.K. Peregrine, A.S. cattle trypanosoma congolense trypanosoma vivax immunodiagnosis experimental infection elisa antigens Sensitivity and specificity of the FAO/IAEA kits for diagnosis of bovine trypanosomosis were investigated using sera from experimental cattle infected by tsetse challenge with cloned populations of Trypanosoma congolense (three populations) or T. vivax (one population). The kits are based on monoclonal antibodies that recognise internal antigens of tsetse-transmitted trypanosomes. Ten cattle were infected with each trypanosome population for at least 60 days, and in combination with unifected cohorts (n=16) were used in a double-blind study design. Sensitivity and specificity of the tests depended on the choice of positive-negative thresholds expressed as percent positivity with respect to the median OD of four replicates of the strong positive reference serum provided with the kit. In general, while overall specificities were high, sensitivities of the antigen-ELISAs were poor. For example, at a cut-off of 5% positivity, the sensitivities of the antigen-ELISAs were 11% for samples (n=1162) from T. congolense infected cattle (n=30), and 24 % for samples (n=283) from T. vivax infected cattle (n=10). The corresponding specificity values were 95% and 79%, respectively. At a cut-off of 2.5% positivity, sensitivity for T. congolense was 25%, and for T.vivax 35%; corresponding specificity values were 85% and 63% respectively. There were no values of the positive-negative threshold at which both sensitivity and specificity were satisfactory. Restricting the analyses to samples taken more than 2 weeks after tsetse challenge did little to improve sensitivity estimates. Trypanosome species specificities of the antigen-ELISAs were also poor. Sensitivity and species specificity of the antigen-ELISA for Typanosoma brucei infections were not investigated. In contrast to the antigen-ELISA, the sensitivity of the buffy-coat technique when applied to the same experimental animals was fairly high at 67% for T. congolense infections and 60 for T. vivax infections. For samples taken more than 2 weeks after tsetse challenge, high sensitivity estimates of 96% for T. congolense and 76% for T. vivax infections were obtained. 1998-11 2013-07-03T05:26:17Z 2013-07-03T05:26:17Z Journal Article https://hdl.handle.net/10568/33243 en Limited Access Elsevier Veterinary Parasitology;79(3): 187-201
spellingShingle cattle
trypanosoma congolense
trypanosoma vivax
immunodiagnosis
experimental infection
elisa
antigens
Eisler, M.C.
Lessard, P.
Masake, R.A.
Moloo, S.K.
Peregrine, A.S.
Sensitivity and specificity of antigen-capture ELISAs for diagnosis of Trypanosoma congolense and Trypansoma vivax infections in cattle
title Sensitivity and specificity of antigen-capture ELISAs for diagnosis of Trypanosoma congolense and Trypansoma vivax infections in cattle
title_full Sensitivity and specificity of antigen-capture ELISAs for diagnosis of Trypanosoma congolense and Trypansoma vivax infections in cattle
title_fullStr Sensitivity and specificity of antigen-capture ELISAs for diagnosis of Trypanosoma congolense and Trypansoma vivax infections in cattle
title_full_unstemmed Sensitivity and specificity of antigen-capture ELISAs for diagnosis of Trypanosoma congolense and Trypansoma vivax infections in cattle
title_short Sensitivity and specificity of antigen-capture ELISAs for diagnosis of Trypanosoma congolense and Trypansoma vivax infections in cattle
title_sort sensitivity and specificity of antigen capture elisas for diagnosis of trypanosoma congolense and trypansoma vivax infections in cattle
topic cattle
trypanosoma congolense
trypanosoma vivax
immunodiagnosis
experimental infection
elisa
antigens
url https://hdl.handle.net/10568/33243
work_keys_str_mv AT eislermc sensitivityandspecificityofantigencaptureelisasfordiagnosisoftrypanosomacongolenseandtrypansomavivaxinfectionsincattle
AT lessardp sensitivityandspecificityofantigencaptureelisasfordiagnosisoftrypanosomacongolenseandtrypansomavivaxinfectionsincattle
AT masakera sensitivityandspecificityofantigencaptureelisasfordiagnosisoftrypanosomacongolenseandtrypansomavivaxinfectionsincattle
AT moloosk sensitivityandspecificityofantigencaptureelisasfordiagnosisoftrypanosomacongolenseandtrypansomavivaxinfectionsincattle
AT peregrineas sensitivityandspecificityofantigencaptureelisasfordiagnosisoftrypanosomacongolenseandtrypansomavivaxinfectionsincattle