Resultados de búsqueda - Cohen’s kappa index

  • Mostrando 1 - 7 Resultados de 7
Limitar resultados
  1. Leaf wetness duration in irrigated citrus orchards in the Mediterranean climate conditions por Bassimba, Daniel, Intrigliolo, Diego S., Dalla Marta, Anna, Orlandini, Simone, Vicent, Antonio

    Publicado 2018
    “…All the sensors and models evaluated showed a substantial strength of agreement with visual observations of LW, with area under the ROC curve of 0.89-0.93 and Cohen's Kappa index of 0.61-0.77. The RH model was recommended because of easier implementation in citrus orchards in Spain. …”
    Enlace del recurso
    Artículo
  2. Calculation of Diagnostic Parameters of Advanced Serological and Molecular Tissue-Print Methods for Detection of Citrus tristeza virus: A Model for Other Plant Pathogens por Vidal, Eduardo, Yokomi, R. K., Moreno, A., Bertolini, Edson, Cambra, Mariano

    Publicado 2017
    “…The total agreement between both detection methods was substantial (Cohen's kappa index of 0.77 +/- 0.03). The diagnostic parameters of each technique (i.e., the sensitivity, specificity, and likelihood ratios) were evaluated in a second test involving 658 Citrus macrophylla nursery plants. …”
    Enlace del recurso
    Artículo
  3. Estimation of the accuracy of two diagnostic methods for the detection of Plum pox virus in nursery blocks by latent class models por Vidal, Eduardo, Moreno, A., Bertolini, Edson, Cambra, Mariano

    Publicado 2017
    “…The agreement between the techniques was almost perfect (Cohens kappa index of 0.88 +/- 0.01). The diagnostic parameters (sensitivity, specificity and likelihood ratios) of both techniques were simultaneously evaluated in 2473 nursery plants by latent class models using maximum likelihood functions and a Bayesian approach. …”
    Enlace del recurso
    Artículo
  4. Enhanced detection of Leptospira in cattle : Comparative performance of loop-mediated isothermal amplification, polymerase chain reaction and serological methods por Hamer, Micaela, Saraullo, Vanina Rosa, Esteban, Micaela, Sanchez, Maria Cristina, Brihuega, Bibiana Felicitas, Martinez, Mara Leila

    Publicado 2025
    “…Notably, LAMP exhibited a high diagnostic sensitivity (100 %, 95 % CI: 93.5–100 %) and specificity (95.4 %, 95 % CI: 93.2–97.0 %), outperforming lipL32 PCR in DNA detection. Additionally, Cohen’s Kappa index (0.792) indicated substantial agreement between LAMP and lipL32 PCR. …”
    Enlace del recurso
    Enlace del recurso
    Enlace del recurso
    Artículo
  5. Real-time on-site detection of the three ‘Candidatus Liberibacter’ species associated with HLB disease: a rapid and validated method por Morán, Félix, Herrero-Cervera, Mario, Carvajal-Rojas, Sofía, Marco-Noales, Ester

    Publicado 2023
    “…The agreement between the two techniques was almost perfect according to the estimated Cohen’s kappa index, with a diagnostic sensitivity and specificity of 83.89% and 100%, respectively, and a relative accuracy of 91.59%. …”
    Enlace del recurso
    Enlace del recurso
    Artículo

Herramientas de búsqueda: